Cool! Poly-B pipe was pulled off the market a few years ago. Now go cut it out and see why..its easier than guessing. Welcome. The kink in the tubing places localized stress at a spot in the wall of the tubing. We are using Pex A and yes, we got all of the fittings at Pex supply. Find the PEX tube that has a problem with the connectors. While doing home inspections, I've noticed that in older neighbourhoods, some houses'copper pipe fittings are practically seeping water, other fittings haveminute water droplets slowly diffusing to the outside. They are cheaper to acquire and to install. I've told them about their problem atleast 6 months but they dont seem to care,today I didn't say anything. Pressure test your piping system according to your local building requirements. Here, we are going to show you how to fix kinks as well as PEX holes and leaking PEX connectors on your own. The image below showsan image of the inside surface of the pipe installed using an expansion fitting. PEX pipes are not actually prone to leaking. I did not expect this at all after the research I have done on this. And IMO, some Civils can make good off-hours plumbers. I think Pierre is on to the key. Sounds silly but its effective. Get home building tips, offers, and expert advice in your inbox. Big box stores sell the crimp tool, but I dont think they sell the expander tool. Copyright 2022 www.tubomart.com. Try it and post your results. Rose, Expert insights on techniques and principles. What then is the permanent solution???? PEXa and PEXb are the most common. Note that there are several different types of PEX on the market. You can use a thermometer to check the temperature. Stress in the PEX material facilitates oxidative degradation of the PEX causing it to become brittle at the high-stress point. So that warranty sounds like it was written by insurers and/or bean-counting lawyers and not by a technical group. Among the most common issues of leaking pipe connections are improper installation practices, especially for push-to-connect fittings. Become a member and get instant access to thousands of videos, how-tos, tool reviews, and design features. The fact you can shove it further onto the barb makes me think you have the wrong fittings. seen it more than once, call a plumber that's not like changing your kitchen sink faucet. The heat gun must have done it then. The connectors are created without the use of solders or chemicals, so even if you put them in tightly, you might see them leak or come apart. This means that even if you installed them tightly, they might still come apart or leak. Pierre- could you elaborate a bit on that and the mechcanical/chemical involvement. Enter Our Dog Days of Summer BBQ Giveaway Now! Any paste flux residue that didn't get hot enough to turn black is still corrosive, but not nearly as corrosive as the water soluble stuff. is definitely pex a. its the souix cheif brand of tube and rings, sold at menards, it does have the ridges on the Rings. Exclusive RemedyIt is expressly agreed that the exclusive remedies under this limited warranty shall be at the option of Wirsbo Company to" issue a refund, repair or replace any article which is proven to be defective. I'll stick with proven technology. Come join the discussion about the industry, safety, finishing, tools, machinery, projects, styles, scales, reviews, accessories, classifieds, and more! Provided the installer wiped the flux after sweating his joints. You could install and acid neutralizer as well. We welcome your comments and After the test, the floor was laid back. Maybe he just bought his pex from people who store it like this..This pic was taken today at a supply house. . New comments cannot be posted and votes cannot be cast. JavaScript is disabled. These connectors are made without using chemicals or solders. Chalk another up forTaunton University of Knowledge FHB Campus at Breaktime. 1995-2022 MH Sub I, LLC dba Internet Brands. Plumbing Zone - Professional Plumbers Forum. I hate to sound like a dinosaur, but this stuff sounds too good to be true. The image below shows, an image of the inside surface of the pipe installed using an expansion fitting. If the pressure remains the same, it means that the pipeline does not leak. The photograph below shows an image of an example of a typical PEX failure at a connection to an expansion fitting. AH i did, sorry sir claim denied failed to use qualified professionals to make alterations to your home. The fittings involve are in a straight line from well to water heater. Since the PEX expansion fittings road system is burie []. I don't believe they're saying this material will fail in one year or ten. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. The fittings usually are metal, with copper or plastic crimp rings. In another case, I reporteda similarcondition to a prospective home buyer, who withdrew his conditionaloffer to purchase. The crimp should be in the middle of the ribbed part of the adapter. Cixi, Ningbo, Zhejiang China 315334, E-Mail:[emailprotected][emailprotected], How To Determine If PEX Expansion Fittings Are Leaking, Since the PEX expansion fittings road system is buried underground, there are certain limitations in inspection and maintenance. "Consider that when you plumb with metal, you don't get any warranty. I have put them on a wet pipe, and had the ring slip. ", Are you suggesting that PEX has either not been proven or has been disproven in its use during the past 25-30 years? Put the jaws of the PEX crimping tool right on top of the ring and bring the two handles together. when it comes right down to it, what difference does it make ? There were over a dozen mechanical crimped joints in the shower area alone! Are you cutting out the Poly-B and replacing with PEX, using Poly-B to PEX conversion adaptors, or going about it another way? The use of expansion fittings places significant additional stress on the wall of the pipe making the pipemore prone to chemical attack and degradation by chlorinated water. As time goes by, the surface temperature gradually rises, and the location of the leaking pipeline will rise to a very high temperature, and a peak will be formed at the leaking point, where the temperature of the leaking point will be much higher than the temperature of other parts of the pipeline. Should we wait a certain amount of time for the line to shrink down? Hello, I was hoping to get the input of some experienced installers on a PEX-A fitting leak. "Actually you do get a 50 yr warranty with copper.http://www.copper.org/applications/plumbing/restools/wrnty/war_doc_txt.htmBut there is not much left after you get past the exclusions. Thanks. Also important to rotate the tool several time during expansion, particularly for 3/4 inch or larger pipe. it seemed like I could twist the fitting back and forth and shove it further onto the Barb and it would stop leaking but I'm worried that it will just start up again later. Acidic water could be your whole problem. :thumbup: I'm just wondering though as I have never used pex, lets just say the hair dryer stops the leak??????????? They can last for up to 200 years given that they are not exposed under direct sunlight. Let the pipe cool down until it turns opaque again. Just looking at these pipes made me nervous. A forum community dedicated to Do it yourself-ers and home improvement enthusiasts. Any help would be extremely appreciated. Helping You to Do It Yourself! Fittings and tubing are cheap, and you sure don't get a warranty with copper (and it can corrode and leak, so it's not foolproof either). The estimated life span of PEX is around 200 years, so you know that this is a strong material. You also need expansion connections to finish this repair. For a better experience, please enable JavaScript in your browser before proceeding. Once the pipeline leaks and other problems are difficult to detect in time, then when the user uses the PEX expansion fittings road system, How can I determine if, How To Ensure No Leakage Of PEX Fittings Plastic Pipe. These weak areas aresticky to the touch, from what appears to be old flux residue (you know how flux drips from a jointwell, the corrosion follows the same pattern). JavaScript is disabled. There are several different types of fittings used to assemble a PEX piping system. Slight damages to the tubings barrier layers will not decrease the tubes integrity. Each method uses different tools and different ring types but their style is similar. Can it be r Hi all,
I don't think that the tool was turned each time. What i meant to say was how might one remove, say, 1 month old dried flux on the soldered joint. Determine the leak location of PEX expansion fittings. A leak exists somewhere in your system if you get a lower initial temperature gauge reading. The electric powered tool does this automatically Not sure if that is the cause though. Im not a licensed electrician either, but I did go to school for it. Then ask the floor heating installer to dry the floor, plan the cement layer, and connect the leaking point with a joint, such as water leakage. *We respect your confidentiality and all information are protected. every single expansion fitting leaked. Sometimes cold temps, cold water may seep on those fittings and the hot air can seal em up. I have a home with a flat roof top. If done by someone not certified, they have no way of knowing if the install was done correctly, thus the difference in warranty time. How might one remove flux remnant after cooling? How to fix pex connection leak - help please. I wish I had read all your comments before I started my plumbing project. As for the warranty - the heck with it. . Has anyone found a failed PEX connection? Here are a few possible reasons your installation is not working: And you waited 8 years to make your very helpful comment! In severe cases, the pipe needs to be replaced. 42 years and still rollin'. The repairs hold just fine. Is it still leaking after such a long time? To prevent the kink from re-developing, you can put a firm bend support to the pipe. If your PEX pipe has a hole, all you need to do is remove the damaged section of the pipe and then use the crimp connection method to fix it: As we have mentioned earlier, PEX connectors can break if you havent installed them correctly. When was the last time you calibrated your crimper? Good fire suppression backup to my ABC extinguisher. Failure to pressure test your system properly can cause leakages and expensive repairs such as the removal of fixtures and your entire floor/wall. All rights reserved. Press question mark to learn the rest of the keyboard shortcuts. Use the PEX 3-part fittings to do this. home improvement and repair website. The pipe is designed tohandle the stress of normal water pressure. "I have learned so much thanks to the searchable articles on the FHB website. Fixing leaking PEX connections and holes in your PEX pipes is not as hard as you think it is.
For clamp/cinch or crimp connection methods, you need to calibrate your tools before you start with your installation. PEX manufacturers (and their insurers!) submitted to our "DoItYourself.com Community Forums". View our Privacy Policy here. However, if the kink occurred on a bent part of the PEX pipe, the kink might re-develop if the said method was used. It's just too good to ignore. Or just suck it up and pay out of your own pocket? As an engineer, your're probably familiar with trade-offs in material selection for projects and the concept of interfaces in systems. Accidental holes may occur, but most plumbing leaks happen at connection spots or joints which are caused by incorrect installation. My electrical answers are based on 2017 NEC, you may have local amendments. You can find sometips for using push-to-connect fittingshere. There are potential problems with the use of expansion fittings including 1) the teeth on the tool damages the inside of the tubing by placing indents into the inside surface, and 2) the stress/strain on the expanded tubing are high as revealed in the finite element stress analysis below. I know you do not walk everywhere you go. wirsbo is a great name, nonetheless. Once the fitting is inserted into the expanded tubing, the tubing shrinks onto the fitting. You just need the right tools to help you make your repairs easier. The use of fittings that are the same diameter as theinside of the PEX pipe and crimp fitting results in a more reliable joint because of the lowerstress. Once the kink disappears completely, stop heating. Is there something I am missing? Plus, get tips for a clean and solid installation. Once the pipeline leaks and other problems are difficult to detect in time, then when the user uses the PEX expansion fittings road system, How can I determine if PEX expansion fittings are leaking? They did the original installation and put in the Pex line that expands over the fittings. Take the go/no-go gauge and look at both the connection. As the name suggests, it is a kind of polyethylene that has cross-links. Put in the support sleeve on this end so that the tube does not collapse. The manufacturers lost a few class action suits because the original plastic fittings failed over time. Any crimps that have been leaking for more than a day or so must be cut out. Not my problem. While PEX is a strong material, there are instances when you encounter problems with it and the common problem is the breaking of PEX connectors. Below are the steps you should follow when heating a PEX tube: Though heating the PEX pipe slightly damages its barrier layers, the PEX tubings core will still be fine. Website operating I have noticed that the Milwaukee and DeWalt power tools do the rotation automatically. One benefit of using cross-linked polyethylene is that it is resistant to freezing. Stephen Hawking: If the government is covering up knowledge of Aliens, they are doing a better job of it then they do at anything else. PEX is the abbreviation for cross-linked polyethylene. Many users are very troubled by the problem of water leakage in the PEX expansion fittings system. The Fora platform includes forum software by XenForo, VerticalScope Inc., 111 Peter Street, Suite 600, Toronto, Ontario, M5V 2H1, Canada. so i developed a leak at an elbow in my cpvc supply lines to the kitchen faucet when i was replacing some cabinets. Plus, they are more affordable and easier to install. If the PEX expansion fittings leak, the pressure will be difficult to maintain for a long time. However, anytime the existing Poly-B is disturbed, the next connection down the line may start to leak a few days to months later. Poly-B on copper fittings with metal compression rings holding them in place. Is he the only plumber in town, Videos make things much easier than it looks at least you had leaks now and not a ripped joint a month later, when your out of town maybe? Place the ring on one end of one tube and a crimp style adapter into one end of the other. Now, ask yourself a simple question: If a house is plumbed with the same material throughout, will it be more reliable than a house plumbed with two different materials mechanically joined at dozens of interface points? Make all your fixture connections homeruns to a manifold, run it places that would be impossible or difficult with copper, snake it through existing walls, etc etc. I have about 12 fittings leaking on the cold water side, As we know when you have an acid problem it will show up on the hot water side first. Copper pipes and fittings have been around longer than most of us have been alive. PEX is often portrayed as a point-point plumbing system when it actually has _mechanical_ crimped connections at almost every fitting. Is it a pinhole leak in the actual brass fitting or is it leaking between the pex pipe and the brass fitting? Thanks for taking the time to respond Reach4, Terry, and breplum. During this process, the kink starts to disappear. Do not touch it. When we were done, we turned on the water and at almost every connection there is a slow drip. 2022 The Taunton Press, Inc. All rights reserved. Sometimes you trust newer technologies like the automobile, over your feet. Yes, I have a house full of the stuff and HATE it. To ensure the good operation of PEX expansion fittings in the later stage, good products and standardized installation are indispensable. They can last for a pretty long time unless you use them in areas exposed to sunlight because this would make them degrade faster. PEX-A pipe with expansion ring not reforming after expansion. My experience is that you need to use the rings with the ridge so the ring does not slide up the pipe during expansion. The fitting is quickly inserted and the PEX shrinks back down with a death grip over the metal fitting. What they're saying is that if the installation is done by a technician trained and certified there is SOME guarantee that it will be installed in accordance with methods approved by the manufacturer.