The terms bonding and grounding are often used together, and in many cases, they're used interchangeably. Pools require plumbing and electrical work, and each of those requires separate permits. The following must be grounded: all electrical equipment associated with the circulation system; all electrical equipment located within 5 feet of the inside wall of the pool water; The electric motors, controllers, and wiring for pool covers shall be located not less than 5 feet (1524 mm) from the inside wall of the pool except where separated from the pool by a wall, cover, or other permanent barrier. b. Receptacle must have an extra-duty, in-use, weatherproof cover that can be closed when the cord is plugged in. Building permitfor pool and barrier. When a heater or pool pump is located more than 3 m (9.8 ft) away, or is isolated by a suitable barrier supplying a spa/hot tub that shares common water circulation with a pool, the Ontario Electrical Safety Code (OESC) does not require ground fault circuit interrupter (GFCI) protection unless it is required by the manufacturer. Semi inground pools will last much longer than the above-ground ones. Building Permit Application for Building, Site Development, Demolition and Zoning Permits (1022.79 Kb) Download PDF file. That means that the wires coming to the pool light J-box must come from a GFCI breaker. In the case of a pool pump breaker size, a 20-amp CB is the best choice to safely support a 240V/ 10-amp (usual setup for pool pumps) electrical system. Electrical bonding of the motors to the pool frame, metal ladders, metal within 5 feet of the pool wall, and related pool equipment shall be #8 solid copper minimum. Installing an inground swimming pool will allow you to spend time. Swimming Pool Gates. A manual disconnect must be visible within 5 from the pools water, and easily accessible near the pool equipment . Most of us are aware that the pool must be bonded, but since 2008 the National Electrical Code (NEC) has mandated that pool water shall be electrically bonded, not just metals in the structure of the pool itself. Studente. Bonding and grounding are two of the most essential electrical safety tasks pool owners must perform. Does your swimming pool have any other electrical needs? The 2008 NEC added a requirement for pool motors to have GFCI protection whenever theyre rated 120V or 240V, 15A or 20A. The Code requirements, if carefully followed, will reduce the electric shock hazards to an acceptable level. In fact, you will likely need a few permits. The pool deck also requires examining. Pedestrian access gates must be self-closing, have a self-latching device at least 54 inches above the ground and open outwards from the pool. Minimum filter motor attachment cord size # 12 A WG. The national average price to repair a pool pipe leak ranges from $600 to $1,400, with most homeowners paying around $900 to repair a leaking pipe. Contact zoning staff at 919-996-2492 or currentplanning@raleighnc.gov to discuss the specifics of your in-ground pool project and general zoning standards relating to walls and/or fences before you begin. Overhead power lines as well as underground wiring represent a shock hazard when in close proximity to swimming pools. What are the grounding requirements for the pool and equipment? All the extra's will add up. Electric pool heaters use electricity to heat the heating element (usually metal coils). Basic models should easily give you a service life of up to 20 years, while the premium or high-end ones can last twice as much (up to 40 years). However, with proper maintenance, some models. Pools are not permitted in the front yard. You can control and automate your pool equipment from the panel or from a remote panel/control. For nonconductive pool shells, bonding at four points shall not be required. 680.22 Electrical equipment other than receptacles and lighting must be a minimum of five feet away fromthe swimming pool unless separated by a barrier. EASY-TO-USE: Intuitive front control panel provides easy operation, service and maintenance. Automatic Pool Cover Motor and key switch 120vlt/15 amp Electrician will need to run conduit from the supply to the key switch location and the key switch to the cover box. Currently it looks like #10 bare solid bond wire was used between pool, screen enclosure, filter pump and spa pump back when pool was installed in 1997. Barrier Requirements: Public Swimming Pools A public swimming pool must be completely enclosed by a fence at least 4 feet in height or a screen enclosure. above grade, such as an aboveground pool, the barrier may be at ground level, such as the pool structure, or mounted on top of the pool structure. In fact, you will likely need a few permits. Section 4207 Covers above ground or temporary pool requirements. Also, check the grout between the tiles to make sure the tile is entirely surrounded and hasnt deteriorated with use. The electric motor and controller shall be connected to a circuit protected by a Pools are permitted in the rear and side yard of a lot. Pool loans exist for individuals who dont have the immediate cash for an installation. Electrical permit located at a minimum of 6 feet from pool wall. Swimming pools shall not be used until all required inspections of the pool, its barrier (fence or pool wall for an above-ground pool), and its associated electrical I want to install a 100 amp sb panel to my existing 200 amp main, about 50 ft away to be closer to the pump and lighting location. Identify the pool equipment: What is the size of the pump and the amperage and voltage circuit requirements. From memory I thought #8 solid was required for code. Public spas must have an emergency disconnect that is visible and at least 5 feet from the spa, but this rule does not apply to single-family dwellings. The pool light must be installed on a GFCI circuit. Minimum ground wire size #12 AWG. Most of us are aware that the pool must be bonded, but since 2008 the National Electrical Code (NEC) has mandated that pool water shall be electrically bonded, not just metals in the structure of the pool itself. One is so you can know what size breaker is needed at the electric box and the other so you know what size of wire to run to the pools pump. For additional information download the requirements for outdoor residential swimming pools pamphlet (PDF). The electrical equipment for swimming pools must be grounded and connected by wiring methods in accordance with the NFPA 70 National Electric Code (NEC). - No overhead electrical conductors should be installed within 15 feet of the pool. The following will be verified: *Proper materials approved for pool installations have been used. Mechanical Permit Application (450.69 Kb) than 10 but not further than 20 from the outside pool wall (Can be existing and/or wired with any approved wiring method) I. The National Electrical Code Article 680-20a1 states that a pool light fixture over 15 volts must be GFCI Protected. 3) Construction Permits Permit fees calculated and provided once permit paperwork is reviewed/approved. Pool & Spa Depot has been installing above ground pools and semi- inground pools for over 20 years. Above-ground pools will not last as long as their average lifespan is 7 to 10 years. The disconnect must be installed within sight of the pool or spa but can be no closer than 5 feet from the pool or spa so that you cannot turn the power on or off while leaning out of the water. Swimming pool pump motor receptacle must be located at least 6 from the inside pool wall, must be grounded, and Ground Fault Circuit Interrupter (GFCI) protected. Take special note of sewer, drainage, fencing, lot line, power lines, fire, and electrical requirements. Run a number 8 copper wire, a grounding ring, around the outside of the pool, 4 to 6 inches below ground level and 18 to 24 inches from the edges of the pool. Thus they require 50 amperes and 240 voltage for function. 47_47 said: I would run a dedicated 40 amp circuit from the house directly to the hot tub and put in a sub panel in the pool house. An electric pool heater is just the generic term for any pool that uses an electric heating element to heat your pool. Convenience receptacle must be Ground Fault Circuit Interrupter (GFCI) protected. A typical above ground pool pump will require a 20-amp breaker and use #12 gauge wire to deliver the electricity. Yes, you will need a pool permit before you can begin construction on an inground pool or an above-ground pool. The electric motors, controllers, and wiring for pool covers shall be located not less than 5 feet (1524 mm) from the inside wall of the pool except where separated from the pool by a wall, cover, or other permanent barrier. At the low end, you could spend as little as $175 fixing a light leak. Save Space; EcoSmart tankless electric water heaters are 90% smaller than traditional tank heaters; may be installed on wall or at point of use; Dimensions 11.5 x 8 x 3.75 inches more. Grounding prevents shock through faults in an electrical system, while bonding prevents shock through differential currents running through the pools metallic components. After crushing and tamping down the debris, gravel is added to the pool cavity, as shown above. - If a fence is metal, it must be grounded to prevent it from becoming electrically charged. The building permit will not be issued until the electrical permit has been applied for. These connectors must be listed for their use. Underground Electrical Inspection After grounding, bonding and all underground Electrical work is completed, the Electrical work shall be inspected before covering. 230 or 115? One of these measures is the bonding together of conductive portions of the pool and metal parts of electrical equipment associated with the pool. The Easytouch panel is a subpanel for breakers, relay center, low voltage transformer for the valve actuators, power source for the salt water generator and a computer. Pool, hot tub and water feature permit application forms include: Download PDF file. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be 4 inches (102 mm). The goal is to provide a means of equalizing the voltage potential of all equipment and parts. The 2011 revision changed 680.21(C) to include 208V by replacing the or with through. The requirements have also been relocated to 680.21 from 680.22 (subsections in 680.22 renumbered accordingly). The very reason the original GFCI circuit breaker tripped indicates that there is something wrong with the circuit, and the GFCI circuit breaker was providing the protection against a potential electric shock. If you need to know the electrical requirements for your inground pool, here is a list of common pool equipment and the approximate volts and amps required for each: Pool Pump: 240v, 10amps Salt Water Chlorinator: 240v, approx 5-8 amps inclusive. maximum depth of 1.0 m (42 in. Required Permits. This doesnt take into account additional costs like fencing, maintenance, and accessories. Pool lighting requires 12 voltage and 3.5 watts to function. Pool Barrier Requirements All outdoor pools, spas and hot tubs must be protected with a barrier (fence) that meets the requirements of the International Swimming Pool and Spa Code, Section 305 . For in-ground pools, there must be at least one GFCI protected outlet that is located between six to ten feet from the edge of the pool. However, because the amount of water the electricity could come in contact with is so large, there are much stricter safety precautions. A 20-amp circuit breaker is a common thing for residential homes. However, some towns and cities require an electrical permit as well, as most pools have an in-ground pump and filtration system that needs to be up to a certain standard. Both grounding and bonding together prevent shock-related injuries and electrocution. The connections of metal by the copper wire allow for electric flow to pass through metal. When the RPM value was reduced to 1730, just over half speed, the power consumption dropped drastically to only 360 Watts, or about 0.36 kW. Do a load calculation for the size of the sub. No pool shall be installed within 27, measured diagonally, from high voltage feeder wire (service entrance cable or utility supply lines). Call the City of Ottawa at 3-1-1 for street lighting locates, which may run alongside or at the back of your property. In the Virginia, Maryland, and D.C. areas, a standard electrical hook-up package for an inground pool will generally cost between $3,500 and $4,500. The goal is to provide a means of equalizing the voltage potential of all equipment and parts. 3) Construction Permits Permit fees calculated and provided once permit paperwork is reviewed/approved. If a lot is less than eighty in width, the pool can be setback five feet from the property lines. UTILITIES REQUIRED Water- for construction and filling of pool Electrical- temporary supply during construction and a You need to know this for two reasons. Contact the Electrical Inspector at (734) 466-2578 if you have questions. The bonding connectors shall be stainless steel, brass, copper, or copper alloy. You may want to be able to switch some lights from your main house out by the pool. One of these measures is the bonding together of conductive portions of the pool and metal parts of electrical equipment associated with the pool. Assume a jacuzzzi or hot tub portion with it? Expect to pay $1000 or more. Above-ground pumps are often available in a 120-Volt variety that can run smoothly with a #12 or #10 wiring gauge and a 20-amp breaker. 4170 New Jersey 42 | Blackwood, NJ 08012 Both are needed to provide safety for anyone entering your pool. Section 4208 II. 680.22 Electrical equipment other than receptacles and lighting must be a minimum of five feet away fromthe swimming pool unless separated by a barrier. In this video we will discuss what your installation consists of and how to operate it. - There must be a continuous fence surrounding the pool, at least four feet high above the ground with a closed, childproof, self-closing gate. The main panel that is feeding the subpanel is grounded. GFCI Protection. Reach out to our professional pool electrician and request more information about our inground pool electrical wiring services. 2. These are often easy to spot by the yellow Test button, and are usually 20 amp breakers. A permit is required for all swimming and bathing pools which the water depth equals or exceeds 24" or the 2) Soil Movement Application Application with pool plans and drainage calculations (if needed) $75 Application fee and $1,500 Escrow fee for Engineering review and inspections. PVC conduit system is required outside. Wiring a sub-panel at the equipment pad to power the pool equipment, 3). Requirements for GFCI protection. Inground pools usually cost between twenty-five and thirty-five thousand dollars. Bonding. 6) No swimming pool shall be located beneath or have any edge of the pool within 10 feet measured horizontally, from an overhead electrical wire, telephone wire, cable TV wire, or any other type of wire. Pool Requirements. Pool heaters often need 240 voltage and 50 amperes. It wont be a surprise if you find one in your electrical box. Note: Electrical bonding associated with a pool or spa must comply with Clause 5.6.2.6 of Australian Standard AS/NZS 3000:2018 (known as the Wiring Rules). Look at the color and condition of the decking material. NEC bonding requirements apply to in ground and above ground pools, and includes all metal components, equipment and the water itself.