Possessing the same accuracy and reliability of the BluVac+ Pro gauge, the BluVac+ Micro is ideal for budget-conscious technicians without sacrificing performance. At this point, the alarm will sound and the display will change to . The BluVac accurately and quickly measures vacuum in Microns, Pascals, Millibar, mmHg, and Torr with a resolution down to 1 micron. The BluVac+ LTE should rarely require recalibration, though it may be necessary to know that your gauge is calibrated properly for full accuracy. The previous calibration will be unchanged. The BluVac+ LTE is now calibrated to factory specifications. Android and iOS devices with Bluetooth connectivity. All products that are found to be faulty within 30 days of purchase will be replaced with brand new products. The indicator on the display will flash, and the backlight will turn off automatically after 1 minute. Under high-pressure conditions ( ), the leak rate indicator shows . Place the BluVac+ LTE undisturbed in an area with a room temperature of at least 23C (73.4F) but no greater than 30C (86F). Copyright var date = new Date(); document.write(date.getFullYear()); [store_name]. % Repeat steps (3) (5) at least three times. Under certain conditions, the display may read ERROR or OIL. Four bars indicate full power.As the battery is depleted, the number of bars displayed decreases, until no bars are left. The BluVac Professional is the most correct and exact vacuum instrument obtainable right now with patented know-how that can't be discovered wherever else. If necessary, remove and detach old battery from battery clip. The ball-valve of the CRT can be closed to completely isolate the system from the pump and hoses, thereby allowing for an accurate rise-time test at the completion of evacuation. Place the dust cap over the vacuum fitting. If the battery power drops to the point where the BluVac+ LTE can no longer function accurately, the alarm will beep 10 times and the power will turn off automatically. Use of a tool to tighten the hook may result in damage to the BluVac+ LTE case. While in this mode, the display will show .Approximately every 35 seconds, the gauge will automatically check the pressure and exit Sleep Mode if the pressure is less than 25,000 Microns. If the sensor inadvertently get contaminated with oil, the display will show OIL indicating the sensor needs to be cleaned for accurate readings. Install the battery as described in the Battery Installation section below. Which gauge is correct?A. When turned on, the icon will flash in the display. Turn the power on by pressing . IntroductionThank you for your purchase of the AccuTools BluVac+ LTE Wireless Digital Vacuum Gauge.Utilizing patented technology, the BluVac+ LTE is the most accurate vacuum gauge available. BluVac is ideal for budget-conscious technicians without sacrificing performance. Accutools BluVac Micro Plus Digital Vacuum Micron Gauge. BacklightTo activate the Backlight temporarily, press once. No. Apply a few drops of rubbing alcohol inside the sensor vacuum port. Please, contact us! $9.95, Continental USA, S&H varies to other areas and countries. Auto Power-OffAfter 1 hour in Sleep Mode, the BluVac+ LTE will automatically turn itself off to further conserve battery power. Unless specified all products carry a minimum 12-month manufacturers return to base warranty. 486 0 obj <>stream The indicator on the LCD display indicates that the sound is on (not muted). The BluVac+ Micro accurately and quickly measures vacuum in Microns, Pascals, Millibar, mmHg, and Torr with a resolution down to 1 micron. The BluVac Micro Plus can be used as a stand-alone vacuum gauge or be paired with the BluVac+ Micro App on an Android and iOS device via Bluetooth for even more capabilities. The item you are trying to purchase is currently out of stock.Please enter your name, email, and phone number below. Clean the plastic enclosure with adamp (not wet) rag. Simple Pulse, Monroe, Origon || waiting for a connection from a mobile app). At this point, it is necessary to replace the batteries (refer to the Battery Installation section above). x\[sGYqDY/@ Replace the oil. Attaching the BluVac+ LTE to the auxiliary port of a vacuum-rated core removal tool (CRT) connected directly to a service port is the best method. Place your finger over the port and shake for a few moments. SoundThe BluVac+ LTE has an internal speaker that will emit a beep for each valid key press, and also functions as an alarm in the Calibration mode (see the Calibration section below). Retailers Wanted || The bars progressively drop as the pressure drops between ATM and 25,000 microns. Nos. Attach the BluVac+ directly to the pump with a short hose or coupler. View and report results of a system evacuation process using the AccuTools BluVac Professional Digital Vacuum Gauge with Bluetooth Smart wireless expertise. The BluVac Plus Micro can operate accurately at temperatures below freezing. A good pump with clean and dry oil will typically pull very quickly to less than 100 microns (generally around 25 microns for a two-stage pump). The BluVac series of Micron Gauges are the only field-calibratable vacuum gauges that require no special equipment for calibration. Regardless, frequent cleaning and/or calibration will not adversely affect the long-term reliability of the instrument. 470 0 obj <>/Filter/FlateDecode/ID[<1D7DC634B539F14693733E75CF475B47>]/Index[396 91]/Info 395 0 R/Length 247/Prev 396053/Root 397 0 R/Size 487/Type/XRef/W[1 3 1]>>stream Mild detergent is acceptable, but use no solvents. For silent operation, the sound can be muted by pressing and holding the key. Each bar corresponds to a vacuum pressure range depending on units according to the following table: Alternate Numeric DisplayThe BluVac+ LTE has an Alternate Numeric Display that can indicate Vacuum Leak Rate. Use our website at www.accutools.com or call us at (954) 227-0781 between 9:00AM and 5:30PM EST. Allow the Gauge to Warm Slowly. AccuTools is a trademark of Core Enterprises, Inc. 3650 Coral Ridge Drive, Suite 101Coral Springs, FL 33065Ph: (954) 227-0781 Fax: (954) 227-1094 www.accutools.com, COVERT WC30-A LTE Wireless Camera Covert WC30-V LTE Wireless Camera Installation Insert batteries, SD card, and SIM card, COVERT WC30-V LTE Wireless Camera Covert WC30-V LTE Wireless Camera Installation Insert batteries, SD card, and SIM card, Wireless Digital Vacuum Gauge Users Guide U.S. Pat. Sporting a large back-lit display, the BluVac operates for up to 100 hours on two AAA batteries and at temperatures below freezing. 500 microns and 77F (25C)). Large, high-visibility back-lit LCD display, Measures Vacuum in Microns, Pascals, Millibar, Millitorr and mmHg, 0 to 25,000 Micron Range with 1 Micron Resolution, Analog Vacuum Level Bar Graph and Evacuation Indicator, Built-in memory retains all previous settings, Rugged, Compact Design with Protective Rubber Boot, Calibration Self Test Can be field calibrated with no special equipment, Ideal for HVAC/R Service and Industrial Use. Additionally, removing the Schrader core(s) via the CRT and using large diameter hoses will greatly speed the evacuation process. Turn off the backlight by pressing repeatedly until the indicator turns off. The indicated pressure will rise due to the small internal volume of the hose or coupler. Small and light enough to fit in a shirt pocket, the BluVac is a full-featured basic micron gauge that utilizes our famous patented BluVac technology to provide the highest accuracy and dependability at the lowest possible cost. BUSINESS ASSOCIATES: on ACCUTOOLS BluVac+ LTE Wireless Digital Vacuum Gauge User Guide, ACCUTOOLS BluVac+ LTE Wireless Digital Vacuum Gauge, ACCUTOOLS A10702 BluVac+ Pro Wireless Digital Vacuum Gauge User Guide, ACCUTOOLS eL-320 Combustible Gas Leak Detector User Guide. Battery Level IndicatorThe battery level indicator shows the relative strength of the battery. Comment * document.getElementById("comment").setAttribute("id","a6c324e2f2cb39df17fc2bbe05159760");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. All rural areas are subject to normal rural delivery times. Allow the sensor to air dry over at least an hour, or pull a vacuum on the sensor to dry it more quickly. Any remaining vapors will cause an incorrect vacuum reading. Ensure the sensor is completely dry before proceeding. For HVAC/R service, always recover refrigerant prior to attaching gauge. We will contact you as soon as this product is available. Oil SensorPrevent oil from being drawn into the Vacuum Sensor. The slow rise in pressure is due to residual refrigerant gas captured in the sensor. If you have a phone set that is configured with payment method, and you know the total of purchase with us, scan this QR code: to process the payment. This affordable digital vacuum gauge will accurately measure vacuum pressure in Microns, Pascals, mBar, Torr, and mmHg with a resolution of 1 micron. REMOVE BATTERY IF THE BluVac+ LTE IS NOT TO BE USED FOR AN EXTENDED PERIOD OF TIME. These features allow an HVAC technician peace of mind as they never having to worry about accuracy, calibration, or having to guess if the gauge is contaminated with oil. With the BluVac Pro, you can accurately measure vacuum pressure in Microns, Pascals, Millibar, Millitorr, mmHg, PSI, and inHg with resolution down to 0.1 micron. With the BluVac+ LTE, you can accurately measure vacuum pressure in Microns, Pascals, Millibar, Millitorr, and mmHg with a resolution of 1 micron. Can I use the BluVac+ LTE to check the proper operation of my vacuum pump?A. AccuTools BluVac LTE Digital Vacuum Gauge, 0 to 25,000 Micron Range with 1 Micron Resolution less than 10,000 Microns, Measures Vacuum in Microns, Pascals, Millibar, Millitorr and mmHg, Large, high-visibility back-lit LCD display, Long battery life Up to 300 Hours on one 9V alkaline battery, Built-in memory retains all previous settings, Rugged, Compact Design About the Size of a Manifold Gauge, Calibration Self Test Can be field calibrated with no special equipment, Sensor withstands overpressure up to 500 PSI, Ideal for HVAC/R Service and Industrial Use, Range 0 - 25,000 Microns (3333.1 Pa, 33.331 mBar, 25,000 mTorr, 25.000 mmHg), Vacuum Accuracy 5% of reading +/- 5 Microns, Vacuum Resolution 1 Microns (0.1 Pa, 0.001 mBar, 1 mTorr, 0.001 mmHg), Vacuum Resolution 1 Microns (at 10,000.0 to 25,000 to 25,000 Microns), Operating Temperature 10F - 122F (-12C - 50C). How often must I calibrate the BluVac+ LTE?A. Always close the blank-off valve and/or disconnect the BluVac+ prior to turning off the pump so as to avoid oil contamination of the sensor. As soon as the power turns on, release and and then press quickly at least three times. Read the vacuum level from the Main Display. 13/3 Workspace DriveHobsonville 0618New Zealand, Privacy Policy Warranty Policy Terms & Conditions. What is the recommended method for attaching the BluVac+ LTE for evacuation service?A. The BluVac+ series of Micron Gauges are the only field-calibratable vacuum gauges that require no special equipment for calibration. Q. If low pressure is still not achieved, the pump may be damaged or worn. The Calibration mode alarm is not affected by the mute status. No. The low-costAccuToolsBluVac+ Micro Wireless Digital Micron Gaugerepresents a breakthrough in economical vacuum measurement. Mobile Milkers || All Auckland orders are delivered the next business day, other main business centres and standard areas are within two-three business days from payment. During Sleep Mode, the backlight will turn off to help conserve battery power, but will turn on again automatically upon resumption of normal operation if it was previously set in the permanent-on mode. Please use the table below to determine and fix the problem: Q. We will contact you as soon as this product is available. The duration is for a period of one year from the date of purchase. Ideal for HVAC/R Service, Industrial, and scientific use. The appropriate units indicator on the LCD display will show Pa, mBar, mTorr, mmHg, or Microns depending on the units set. Prior to further use of the BluVac+ LTE, clean the sensor as described in the Cleaning the Vacuum Sensor section below. 396 0 obj <> endobj SpBRX':F2fUyp7y.K`0?Qo/6S^Ao6Ds"z At this point, the alarm will sound, and will show on the display. <> The gauge can be manually brought out of Sleep Mode by pressing any key on the keypad. Take care not to expose thevacuum sensor to oil. 8,504,313, 8,768,633, 8,976,939 BluVac+ Professional Users Guide Introduction Thank, 4G LTE LTE CPE Wireless WiFi Router User Manual Product Overview Get to know your LTE Indoor CPE, Your email address will not be published. We supply New Zealand with high quality HVAC/R tools. Key Features of the Pro model over other models: PISG display, Saturation Temperature display, Vacuum Rise Time Analyzer, minimum pass time analysis (15 min. Signup user-based site at https://viot.us/HVAC, discount provided for frequent buyers, group buyers, HVAC school instructors, and retailers there. Remove from freezer and press any key to silence the alarm. The BluVac+ Micro can be operated stand-alone or in conjunction with an iOS or Android compatible app. Pronounced Micro BluVac,BluVac Digital Micron Gauge represents a breakthrough in economical vacuum measurement. The micron gauge will power off completely after one hour in Sleep Mode. (170g) including Battery and Swivel HookDimensions: 3.5 x 3 x 1.25 (9cm x 7.5cm x 3cm)Wireless Range: Up to 100m (328) Line-of-Sight. Q. 5 0 obj Attach the BluVac+ LTE to the system to be evacuated with a high quality vacuum hose. When the battery is replaced, and the BluVac+ LTE is turned back on, the BluVac+ LTE will resume operation with all previous settings intact. Press and hold (do not release) the key for about 5 seconds. Ensure the pump ballast is completely closed and the blank-off valve is completely open, and all fittings are tight and seals are not damaged. Delivery is by courier from Auckland, delivery times may vary. Wireless OperationPress and release to turn the Bluetooth radio on and off. When not inuse, the dust cap should remain in place over the sensor port. Unlike any other vacuum gauge, the BluVac+ LTE can be easily recalibrated to factory specifications without any special equipment, with the following procedure: NOTE: For accurate calibration, it is necessary to allow the BluVac+ LTE to warm slowly. Except to the extent prohibited by applicable law, any implied warranty or condition of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Ideal for the HVAC/R professional, the BluVac+ LTE is small, lightweight, rugged and easy to use, Range: 0 25,000 Microns (3333 Pa, 33.330 mBar, 25,000 mTorr, 25.000 mmHg)Vacuum Accuracy: 5% of Reading +/- 5 MicronsVacuum Resolution: 1 Micron (1 Pa, 0.001 mBar, 1 mTorr, 0.001 mmHg)Warm-up Time: InstantResponse Time: InstantPower: 9V Alkaline Battery (9V Lithium recommended for low temperature operation)Battery Life: Up to 300 Hours (Bluetooth Disabled)Operating Temperature: 10F 122F (-12C 50C)Maximum Overpressure: 1,000 PSIVacuum Port Fitting: Male Flare Nickel Plated for Durability with Dust CapWeight: 6 oz. Clean the Vacuum Sensor and Restart Calibration, Restart Calibration. Allow the BluVac+ LTE to warm to 20C (68F). This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or jurisdiction to jurisdiction. Turn the BluVac+ off, warm the vacuum port with your hand, turn the BluVac+ back on. In stock (can be backordered). Usually, since strain is used under regular atmospheric s Munters PsychroApp%eighty four is the quick and simple psychrometric calculation tool for making accurate calculations of the thermodynamic properties of moist air.Calculate the complete, smart, latent and moisture hundreds of any process extra accurately than utilizing psychrometric Our Gntner Refrigeration Engineering App presents refrigeration engineering know-how in the form of information, info and helpful features.News: Current info about GntnerMaterial advice: Displays the chemically and technically best material mixture for a massive number of frequ HVAC Calculator allows performing completely different calculations for HVAC methods engineering.The program is a complex, unique by its size and content, comprising 38 calculations, vital for any HVAC engineer.Now all the most up-to-date calculations are readily out th Download the testo APP Refrigeration to your Smartphone / Tablet for free and make your everday work at AC/R Systems more comfy.Features:%eighty Remote view of your measured values on a Smartphone / Tablet%eighty Track adjustments utilizing the graphical trending opera Connect to Bluetooth-enabled instruments for component diagnostics. %PDF-1.7 % If the OIL indicator on the display illuminates, this is an indication that the vacuum sensor has been contaminated and is no longer functioning accurately. *} Milkersupply.com || Maine || Attempting to accelerate the warming by using a heat source will not provide satisfactory results. The BluVac + Micro Vacuum Gauge is great for HVAC professionals because it is small, lightweight, rugged easy to use, and affordable. With this app related to an iDVM multimeter it is attainable to:%eighty Remotely view electric With measureQuick HVAC you can measure diagnose system problems from the most trivial to the most complicated. Did I damage the BluVac+ LTE?A. The Micro Plus displays HI-P when the vacuum pressure exceeds 25,000 Microns. Q Yt27v. COVERT WC30-A LTE Wireless Camera User Guide, COVERT WC30-V LTE Wireless Camera User Guide, 4G LTE LTE CPE Wireless WiFi Router User Manual, Maxxima MRL-S41503 4 Round Anti-Glare Instruction Manual, Shenzhen Yaohui Technology LK206 Wireless Charging Station User Manual, allard Navigait Foot Drop Mild Stability Instruction Manual, HART HLCG01 40V Lithium-ion Battery Charger Instruction Manual, CNP BRANDS 031865 Ezi Baby Bouncer Instruction Manual, Panasonic Corded Cordless Phone User Guide, GE Appliances GDF550PGR Front Control Dishwasher Installation Guide. Email : info@hvactools.co.nz The AccuTools BluVac Professional Digital Vacuum Gauge is the most accurate and precise vacuum instrument available today with patented technology that cannot be found anywhere else. stream 1 x BluVac+ Micro Wireless Digital Micron Gauge, Female-to-Female Flare Coupler, Storage/Carrying Pouch, Batteries (Two AAA Alkaline), Instruction Manual. Unlike all other micron gauges, the accuracy of the BluVac+ LTE is independent of temperature and pressure. Please contact us for Return Authorisation before returning. The CAL indicator should illuminate, and should show on the Main Numeric Display. To operate the BluVac+ LTE as a basic vacuum gauge: WARNING: To avoid damaging the BluVac+, only hand-tighten sensor connection. All rights reserved. Restart Calibration. BluVac+ Micro Wireless Digital Micron Gauge English Manual. Place the BluVac+ LTE in a clear Ziploc (resealable zipper storage) bag, press out any extra air, and seal. Pumpete Brand mobile milker base. If you are not completely satisfied with your purchase, simply contact us to return it within 30 days in the original packaging and condition supplied for a full refund. %%EOF The Leak Rate Indicator is useful for determining the size of a vacuum leak, if one exists, or the presence of moisture or outgassing. Swivel HookThe BluVac+ LTEs removable stainless steel swivel hook enables hanging of the gauge and will allow it to swivel freely in any direction. We will be happy to help. Connecting New Zealand businesses with recognised global HVAC/R + electrical manufacturers with great service and support, every day. The gauge may be operated with or without the hook attached. Ideally, the BluVac+ LTE should be as close to the internals of the system under evacuation, and as far from the vacuum pump as possible. If possible, always close the blank-off valve on the vacuum pump prior to turning the vacuum pump off. WARNING: To avoid personal injury and to prevent damage to the BluVac+ LTE Digital Vacuum Gauge, never exceed 1,000 PSI. If not, turn the power off again and repeat. Important: Expose the BluVac+ LTE to atmospheric pressure. This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Need Help? Range and ResolutionThe BluVac+ LTE has a broad vacuum pressure measurement range and very high resolution according to the table below: The Vacuum Level Bar Graph has two modes: Evacuation Progress IndicatorWhen the pressure is above 25,000 microns (when the display shows ), the Bar Graph indicates evacuation progress. It will also beep every 5 minutes in Sleep Mode. Home ACCUTOOLS ACCUTOOLS BluVac+ LTE Wireless Digital Vacuum Gauge User Guide. Leave the Gauge Undisturbed During Warming Phase. Replace battery cover by aligning tab and snapping back into place. Q. Ive attached the BluVac+ LTE directly to my pump with a short hose or coupler. The state of moist air is shown by pressure, dry-bulb temperature, relative humidity, specific enthalpy, specific quantity bulk, and so on. hAJBQ/^OphD7 ( BA$A D4i Allow the BluVac+ LTE to cool to below -2C (28.4F). (M,G9Jp~U?,,Jyk_N z}in:~qFigYw:!]ifwysB F?.wfc/.1o1/a&:whqz~k\BYMU:*1^Cj}GRc'9 \ps2!F8hb.KrAy.I,f.t `NsggjCpyI]iNZC4T Any shipping damage resulting from improper packaging shall be the responsibility of the Purchaser.